Enable SR-IOV Virtualization¶
SR-IOV (Single Root Input/Output Virtualization) can isolate PCIe devices to improve performance that is similar to bare-metal levels. SR-IOV consists of two basic units: PF (Physical Function), which supports SR-IOV PCIe extended capability and manages entire physical devices; and VF (Virtual Function), a “lightweight” PCIe function that is a passthrough device for VMs.
For details, refer to Chapter 9 of PCI-SIG’s PCI Express Base Specification Revision 4.0, Version 1.0.
SR-IOV Architectural Overview¶
SI - A System Image known as a VM.
VI - A Virtualization Intermediary known as a hypervisor.
SR-PCIM - A Single Root PCI Manager; it is a software entity for SR-IOV management.
PF - A PCIe Function that supports the SR-IOV capability and is accessible to an SR-PCIM, a VI, or an SI.
VF - A “light-weight” PCIe Function that is directly accessible by an SI.
SR-IOV Extended Capability¶
The SR-IOV Extended Capability defined here is a PCIe extended capability that must be implemented in each PF device that supports the SR-IOV feature. This capability is used to describe and control a PF’s SR-IOV capabilities.
PCIe Extended Capability ID - 0010h.
SR-IOV Capabilities - VF Migration-Capable and ARI-Capable.
SR-IOV Control - Enable/Disable VFs; VF migration state query.
SR-IOV Status - VF Migration Status.
Initial VFs - Indicates to the SR-PCIM the number of VFs that are initially associated with the PF.
Total VFs - Indicates the maximum number of VFs that can be associated with the PF.
Num VFs - Controls the number of VFs that are visible. Num VFs <= Initial VFs = Total VFs.
Function Link Dependency - The field used to describe dependencies between PFs. VF dependencies are the same as the dependencies of their associated PFs.
First VF Offset - A constant that defines the Routing ID offset of the first VF that is associated with the PF that contains this Capability structure.
VF Stride - Defines the Routing ID offset from one VF to the next one for all VFs associated with the PF that contains this Capability structure.
VF Device ID - The field that contains the Device ID that should be presented for every VF to the SI.
Supported Page Sizes - The field that indicates the page sizes supported by the PF.
System Page Size - The field that defines the page size the system will use to map the VFs’ memory addresses. Software must set the value of the System Page Size to one of the page sizes set in the Supported Page Sizes field.
VF BARs - Fields that must define the VF’s Base Address Registers (BARs). These fields behave as normal PCI BARs.
VF Migration State Array Offset - Register that contains a PF BAR relative pointer to the VF Migration State Array.
VF Migration State Array - Located using the VF Migration State Array Offset register of the SR-IOV Capability block.
For details, refer to the PCI Express Base Specification Revision 4.0, Version 1.0 Chapter 9.3.3.
SR-IOV Architecture in ACRN¶
A hypervisor detects an SR-IOV capable PCIe device in the physical PCI device enumeration phase.
The hypervisor intercepts the PF’s SR-IOV capability and accesses whether to enable/disable VF devices based on the
VF_ENABLE
state. All read/write requests for a PF device passthrough to the PF physical device.The hypervisor waits for 100ms after
VF_ENABLE
is set and initializes VF devices. The differences between a normal passthrough device and SR-IOV VF device are physical device detection, BARs, and MSI-X initialization. The hypervisor usesSubsystem Vendor ID
to detect the SR-IOV VF physical device instead ofVendor ID
since no validVendor ID
exists for the SR-IOV VF physical device. The VF BARs are initialized by its associated PF’s SR-IOV capabilities, not PCI standard BAR registers. The MSI-X mapping base address is also from the PF’s SR-IOV capabilities, not PCI standard BAR registers.
SR-IOV Passthrough VF Architecture in ACRN¶
The SR-IOV VF device needs to bind the PCI-stud driver instead of the vendor-specific VF driver before the device passthrough.
The user configures the
acrn-dm
boot parameter with the passthrough SR-IOV VF device. When the User VM starts,acrn-dm
invokes a hypercall to set the vdev-VF0 device in the User VM.The hypervisor emulates
Device ID/Vendor ID
andMemory Space Enable (MSE)
in the configuration space for an assigned SR-IOV VF device. The assigned VFDevice ID
comes from its associated PF’s capability. TheVendor ID
is the same as the PF’sVendor ID
and theMSE
is always set when reading the SR-IOV VF device’s control register.The vendor-specific VF driver in the target VM probes the assigned SR-IOV VF device.
SR-IOV Initialization Flow¶
When an SR-IOV capable device is initialized, all access to the configuration space will passthrough to the physical device directly. The Service VM can identify all capabilities of the device from the SR-IOV extended capability and then create a sysfs node for SR-IOV management.
SR-IOV VF Enable Flow¶
The application enables n
VF devices via an SR-IOV PF device sysfs
node.
The hypervisor intercepts all SR-IOV capability access and checks the
VF_ENABLE
state. If VF_ENABLE
is set, the hypervisor creates n
virtual devices after 100ms so that VF physical devices have enough time to
be created. The Service VM waits 100ms and then only accesses the first VF
device’s configuration space including Class Code, Reversion ID, Subsystem
Vendor ID, Subsystem ID. The Service VM uses the first VF device
information to initialize subsequent VF devices.
SR-IOV VF Disable Flow¶
The application disables SR-IOV VF devices by writing zero to the SR-IOV PF
device sysfs
node. The hypervisor intercepts all SR-IOV capability
accesses and checks the VF_ENABLE
state. If VF_ENABLE
is clear, the
hypervisor makes VF virtual devices invisible from the Service VM so that all
access to VF devices will return 0xFFFFFFFF
as an error. The VF physical
devices are removed within 1s of when VF_ENABLE
is clear.
SR-IOV VF Assignment Policy¶
All SR-IOV PF devices are managed by the Service VM.
Currently, the SR-IOV PF cannot passthrough to the User VM.
All VFs can passthrough to the User VM, but we do not recommend a passthrough to high privilege VMs because the PF device may impact the assigned VFs’ functionality and stability.
SR-IOV Usage Guide in ACRN¶
We use the Intel 82576 NIC as an example in the following instructions. We only support LaaG (Linux as a Guest).
Ensure that the 82576 VF driver is compiled into the User VM Kernel (set
CONFIG_IGBVF=y
in the Kernel Config).When the Service VM boots, the
lspci -v
command indicates that the Intel 82576 NIC devices have SR-IOV capability and their PF drivers areigb
.Input the
echo n > /sys/class/net/enp109s0f0/device/sriov\_numvfs
command in the Service VM to enable n VF devices for the first PF device (enp109s0f0). The number n can’t be more than TotalVFs coming from the return value of commandcat /sys/class/net/enp109s0f0/device/sriov\_totalvfs
. Here we use n = 2 as an example.Passthrough an SR-IOV VF device to guest.
Unbind the igbvf driver in the Service VM.
modprobe pci\_stub
echo "8086 10ca" > /sys/bus/pci/drivers/pci-stub/new\_id
echo "0000:6d:10.0" > /sys/bus/pci/devices/0000:6d:10.0/driver/unbind
echo "0000:6d:10.0" > /sys/bus/pci/drivers/pci-stub/bind
Add the SR-IOV VF device parameter (
-s X, passthru,6d/10/0
) in the launch User VM scriptBoot the User VM
SR-IOV Limitations in ACRN¶
The SR-IOV migration feature is not supported.
If an SR-IOV PF device is detected during the enumeration phase, but not enough room exists for its total VF devices, the PF device will be dropped. The platform uses the
MAX_PCI_DEV_NUM
ACRN configuration to support the maximum number of PCI devices. Make sureMAX_PCI_DEV_NUM
is more than the number of all PCI devices, including the total SR-IOV VF devices.